IH: Hold current-maximum current at which the device will not trip at 25℃ |
Pdmax: Power dissipated from device when in the tripped state in 25℃ still air |
It: Trip current-minimum current at which the device will always trip at 25℃ |
R max: Maximum device resistance at 25℃ prior to tripping |
Vmax: Maximum voltage device can withstand without damage at rated |
R min: Minimum device resistance at 25℃ prior to tripping |
Imax: Maximum fault current device can withstand without damage at rated |
Time-to-trip: Over loading current & time |